 ENHANCED BARRIER SYSTEM : Sardinia Paper: 2 of 3

This paper was presented in Sardinia in July 2007 by K.R. Legge, P.A. Legg and P.J. Meyer.

On this page : Slides 14 - 25

The method of degradation of a polymer membrane is well documented.

And the rate at which a high density polyethylene geomembrane will degrade has been recorded in several recent publications. We should remind ourselves of the 2005 Rankine lecture which brought our attention to the even further reduction in service life of a geomembrane at eleveated temperature and exposed to leachate. It has been argued that, in an anaerobic condition, there is insufficient oxygen to allow fur further oxidation of a membrane. However, this does not recognise the free oxygen available beneath the geomembrane within the soil or clay components beneath the membrane.

The extent of dessication cracking of clay components and barriers is commonly known; and

The significant increase in the rate of diffusive losses for relatively small increases in temperature has been quantified.

Other problems associated with service life include the build-up of gases beneath liner systems and spontaneous combusion of landfills.

Thus we know that the primary problems associated with containment performance are related to increased temperature which results in a reduced polymer service life, an increase in desiccation cracking and GCL shrinkage with consequent increase in advective losses and accelerated diffusive losses.

A coupled solution was thus proposed which makes use of the adjacent permeable drainage layer or leak detection system to draw a fluid through under negative pressure, which would allow for the removal of diffused VOCs, the removal of heat so as to reduce the temperature to which the barrier is exposed and the introduction of moisture to hydrate and maintain the clay component in hydrated condition.

This is shown schemtically in the diagram where the blue line represents the fluid drawn through the pervious layer under a negative pressure.

Three test series were undertaken to evaluate the performance of this coupled solution comprising laboratory hydration and temperture tests and an in-situ fields tests on different management.

The hydration tests undertaken in the laboratory of the University of the Witwatersrand comprised passing air through a water bath and then through an envelope of geosynthetic materials representing a typical primary composite liner with geosynthetic drainage layer and underlying geomembrane.

On the right hand side, the water bath can be seen and, on the left hand side, typical geosynthetic envelopes representing statutory composite liner requirements.

The results of these tests show a rapid increase in moisture content of the GCL layer within the geomembrane envelope as the Bentomat absorbs moisture. Within a short period, the rate of moisture absorption reduces as the Bentomat swells reducing permeabilty. Uniform distribution of moisture was noted over the length of the sample and the horizontal tests show the higher moisture absorption due to ponding within the leak detection system of condensed water.

Continued

Sardinia Paper: 1 of 3 | 2 of 3 | 3 of 3

2009 END

Liner Applications \ Technical Specs \ Typical Drawings \ Seaming Systems \ Applications
 Product Range : Geomembranes \ Geosynthetic Clay Liners \ Geo Drains \ Containers
Quality Assurance \ Contract History \ Company Profile \ Contact Us \ Disclaimer \
Home

Aquatan holds SABS ISO9001 2008 and IAGI Status

10 Diesel Road
PO Box 633
Isando 1600
South Africa

Telephone: +27 (0)11 974 5271
Fax:      +27 (0)11 974 4111
E-mail:    aqua@aquatan.com
GPS Coordinates: S 26 08.504 E 2812.155

All Contents Copyright © 2012 Aquatan (Pty) Ltd. | Webmaster: Celestine Ventures cc
 Date of entry: February 2004 | Latest Upload: 06 December, 2013

get_adobe_reader02